http://WWW.LUTRONMETER.COM
INSTRUMENTSZONE 571b78d19ec66f109851c64a False 166 1273
OK
background image not found
Found results for
'field service'
Fluke 77 IV Digital Multimeter INR   34700 INR  34700
-0%

Fluke 77 IV Digital Multimeter

Versatile meters for field service or bench repair. The Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view. It measures: · Wide 1000 V measurement range · Average responding AC measurements · 0.3% accuracy · 10 Amps continuous (20 A for 30 seconds) · Frequency and capacitance · Resistance and continuity Features · Large display · Backlight for work in dim areas · Min / Max to record signal fluctuations · Ergonomic overmolded housing with integrated probe holders · Free your hands with the optional TPAK magnetic hanger · Auto and Manual ranging · Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards

INR 34700 INR 34700

Availability:True

Pay mode:COD only

view details
Amprobe TMD-50 Thermocouple Thermometer K-type INR   9200 INR  9200
-0%

Amprobe TMD-50 Thermocouple Thermometer K-type

Model No. TMD-50 FEATURES:- Highly accurate thermometer with 0.1% basic accuracy for precise measurements Dual input T1, T2, T1-T2 Large, backlit easy to read display In-field thermocouple offset adjustment °C/°F selection Robust protective Holster Auto-Power Off MIN/MAX/HOLD functions Average /Relative Zero Functions Users manual, K-type thermocouple, Batteries(4)

INR 9200 INR 9200

Availability:True

Pay mode:COD only

view details
Amprobe 15XP-B Digital Multimeter VolTect™ Non-Contact Voltage Detection INR   8800 INR  8800
-0%

Amprobe 15XP-B Digital Multimeter VolTect™ Non-Contact Voltage Detection

MODEL NO. 15XP-B FEATURE The 15XP-B is the right choice for electronics engineers, technicians and field service Autoranging display for faster measurements TTL logic test for digital circuits Integrated tilt stand for easy bench use Diode test for component level troubleshooting Data hold freezes display to “hold" measurement reading 600V AC / 600V DC—highest voltage rating in this size of meter Special 2000 MΩ measurement range

INR 8800 INR 8800

Availability:True

Pay mode:COD only

view details
Fluke 80PK-8 Pipe Clamp Temperature Probe INR   41600 INR  41600
-0%

Fluke 80PK-8 Pipe Clamp Temperature Probe

MODEL NO. 80PK-8 · The Fluke 80PK-8 Pipe Clamp Temperature Probe uses Type-K thermocouple for fast temperature and superheat measurements of pipe surfaces. The 80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe is designed to reliably measure the temperature of pipes ¼-inch (6 mm) to 1 3/8-inch (35 mm) in diameter, at temperatures between -29°C and 149°C (-20°F and 300°F), while retaining a long service life. Durable ribbon sensor Measurement range: -29 to 149 °C for pipe diameters from 6.4 to 34.9 mm One year warranty

INR 41600 INR 41600

Availability:True

Pay mode:COD only

view details
FLUKE 85RF HIGH FREQUENCY PROBE INR   27700 INR  27700
-0%

FLUKE 85RF HIGH FREQUENCY PROBE

MODEL NO. 85RF · The 85RF High Frequency Probe is designed to convert a DC voltmeter with a input impedance of 10M ohms into a high frequency (100 kHz to 500 Mhz) RF voltmeter. Conversion from AC to DC is accomplished on a one-to-one basis includes a range of 0.25 to 30 Vrms. The probe's DC output is calibrated to be equivalent to the rms value of a sine wave input. Specifications Voltage range 0.25 to 30 Vrms Maximum input voltage 30 Vrms, 200 VDC AC to DC ratio 1:1 Ratio Accuracy (At 25 MHz and loaded with 10 M ohm) Above 0.5 V ±0.5 dB Below 0.5 V: ±1.0 dB Add ±0.2 dB in RF fields of 1 to 3 V/m Frequency response (relative to 25 MHz) 100 KHz to 100 MHz ±0.5 dB 100 MHz to 200 MHz ±2.0 dB 200 MHz to 500 MHz ±3.0 dB

INR 27700 INR 27700

Availability:True

Pay mode:COD only

view details
FLUKE I50S, AC SCOPE CURRENT PROBE, 50MHZ INR   302200 INR  302200
-0%

FLUKE I50S, AC SCOPE CURRENT PROBE, 50MHZ

MODEL NO. i-50S · Designed for use with bench oscilloscopes, the i50s Current Probe offers an ergonomic, robust and high performing solution for the measurement of DC and AC currents up to 50 MHz. With a permanent nominal current of 30 A RMS and a measuring capacity of 50 A for 10 s, as well as exceptional immunity to high common mode voltages (dv/dt = 5 kV/_s,) amplitude = 1,5 kV, error < 0,05% of IPN), the i50s considerably widens the possibilities of accurate measurement of commutation currents. Bandwidth DC up to 50 MHz Nominal current 30 A Max. current 50 A, < 10 s Automatic zero adjustment and degauss functions Overheating and head unlocked warning Rise time < 7 ns External magnetic field rejection rate AC and DC 60 dB Rejection rate of fast dv/dt (5kV/_s) < 15 mA t Electrical Characteristics Nominal current (In) ± 30 A DC or A rms Measuring range (duration < 10 s) I max ±50 A pk Output sensitivity low range 1 V/A (1 MΩ) High range 100 mV/A (1 MΩ) Overall accuracy (DC to 100 Hz at 25°C ±0.5% at In typical ±1.5% at I max Gain variation (max) ±0.04% of rdg / °C Step response in Data Sheet Frequency response in Data Sheet Insertion impedance (ZI) in Data Sheet < 0.1 Ω up to 10 MHz < 0.4 Ω 10 MHz to 50 MHz External magnetic field rejection rate 60 dB (AC and DC) Rejection rate of fast dV/dt at 5 kV/ μs < 15 m At (during dV/dt) Output noise level (measured with a filter at 25 MHz) 1 m At rms typical Output noise level (measured with a filter at 25 MHz) 9 mA tpp Dynamic Characteristics Bandwidth DC to 50 MHz(-3dB) Frequency derating (see Figure 4) 10 A at 10 MHz Rise time, (10% to 90%) < 7 ns Delay time < 25 ns Overshoot < 5% of reading General Characteristics Aperture dimensions 5 x 5 mm (0.2 in x 0.2 in) Max primary conductor temp 60° C (140°F) Dielectric withstand 1350 Vrms / 50 Hz / 1 min Working voltage 300 Vrms or DC (CAT I) 150 Vrms or DC (CAT II) Operating temperature °C to + 40°C (32°F to 104°F) Storage temperature -10°C to + 60°C (14°F to 140°F) Maximum altitude 2000 m (6600 ft) Maximum relative humidity 80% , 31°C (87°F) Environment Indoor use only Power supply ±12 V ± 0.5 V Current consumptions at nominal 30 A 550 mA Current consumption during demagnetization 1.3 A (for 6 s) Probe Output cable length 2 m (6.6 ft)

INR 302200 INR 302200

Availability:True

Pay mode:COD only

view details
FLUKE TL40 RETRACTABLE TIP TEST LEAD SET INR   5000 INR  5000
-0%

FLUKE TL40 RETRACTABLE TIP TEST LEAD SET

MODEL NO. TL-40 · One pair (red, black) of test leads with sharp needle point tips adjustable to desired length from 0 to 76 mm · Extra hard probe tips to provide long service life · Flexible silicone insulated test leads · CAT II 600 V, 3 A rating Fluke TL40 Retractable Tip Test Lead Set

INR 5000 INR 5000

Availability:True

Pay mode:COD only

view details
FLUKE i-6000S FLEX AC CURRENT PROBE INR   94500 INR  94500
-0%

FLUKE i-6000S FLEX AC CURRENT PROBE

MODEL NO. i-6000S FLEX-36 FEATURE · The i6000sflex is an AC current probe utilising the Rogowski principle. It can be used to measure currents up to 6000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas. Electrical Characteristics Current ranges 60 A / 600 A / 6000 A AC rms Output sensitivity (AC coupled) 50 mV /5 mV / 0.5 mV per A Load impedance 100 kOhm minimum Accuracy (at +25°C) ±1% of range (45 – 65 Hz) Linearity (10% to 100% of range) ±0.2% of reading Noise 8 mV AC rms (60 A) 2 mV AC rms (600/6000 A) Frequency range 10 Hz to 50 kHz (-3 dB) Phase error < ±1° (45 – 65 Hz) ±10° (at 20 kHz) Position sensitivity (with cable > 25 mm from the coupling) ±2% of range External field (with cable > 200 mm from the head) ±1% of range Power supply 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply Temperature coefficient ±0.08% of reading per ° C Working voltage (see Safety Standards section) 600 V AC rms or DC General Characteristics Head cable length (double insulated) 610 mm (24 in) I6000s Flex-24 915 mm (36 in) I6000s Flex-36 Head cable diameter 14.3 mm Head bend radius 38.1 mm Cable length (head to electronics) 2 m Output connection 0.5 m cable terminated with safety BNC connector Supplied with 4 mm safety plug adaptor Operating temperature range -20 to +90°C (head) -20 to +85°C (electronics) Storage temperature range -40 to +105°C (head) -20 to +85°C (electronics) Operating humidity 15% to 85% (non condensing) Weight 180 g (head), 190 g (electronics) Safety Standards BS EN 61010 1: 2001 BS EN 61010 2-032: 2002 BS EN 61010 031: 2002 600 V rms, Category III, Pollution degree 2 EMC standards BS EN 61326: 1998 +A1, A2, and A3

INR 94500 INR 94500

Availability:True

Pay mode:COD only

view details
1
false