METRAVI CE-500F DIGITAL FREQUENCY METER MODEL NO. CE-500F 999.9 Hz 4 Digits, Panel Flush Mounting, 96 X 48 mm sq, Input 50 - 500V, Measuring range 0 - 999.9 Hz Description Microprocessor based 4 digit display. Available for ranges: 99.99Hz, 999.9 Hz, 10KHz and 100KHz ranges. Available in 96 * 96 and 96*48 mm Bezel sizes. Auxiliary Power Supply: 230V AC 50Hz / 110V AC 50Hz / DC Auxiliary inputs also available
LUTRON AQ-9901 SD AIR QUALITY METER FEATURES * Real time recorder, save the data into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic analysis by themselves. under the Excel software. * At the same time, the SD memory card can record 3 probe\'s data ( %RH/CO2/O2/Temp. or %RH/CO2/CO/Temp. ) along with the time information into the one Excel file at the same time. * Manual datalogger is available, during execute the manual datalogger function, it can set the different location no. ( position 1 to position 99 ). * Air quality measurement application, multi-function : CO2 (Carbon dioxide ), CO ( Carbon monoxide ), O2 ( Oxygen in air ), Humidity, temperature measurement. * CO2range:0to4, 000ppmx1ppm. * O2range:0to30.0%x0.1%. * COrange:0to1, 000ppmx1ppm. * Humidity range: 10 to 95 %RH. * Dew point Temp. and Wet bulb Temp. measurement. * Temp. range : 0 to 50.0 °C, °C/°F. * CO2 sensor : NDIR, long term reliability. * CO, O2 sensor : Galvanic cell type. * Humidity sensor : Precision capacitance sensor * Alarm setting with the beeper sound output. * Sampling time for data recorder is 2 seconds to 8 hours. * Complete set with 4 probes :CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe, Humidity/Temp. probe, main meter and the hard carrying case. * Separate probe, easy for remote measurement. * Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional. * RS232/USB computer interface.
LUTRON SL-4001, IEC 61672 CLASS 2 SOUND LEVEL METER DIGITAL SOUND LEVEL METER Model : SL-4001 FEATURES * Large LCD display, easy to read. * Max. Hold function for stored the maximum value on display. * Frequency weighting networks are designed to meet the * Warning indicator for over and under load. IEC 61672 CLASS 2. * LCD display for low power consumption & clear read-out even * A & C weighting networks are conformity to standards. in bright ambient light condition. * Time weighting(FAST & SLOW) dynamic characteristic modes. * Used the durable, long-lasting components, including a strong, * AC/DC output for system expansion. light weight ABS-plastic housing case. * Build in adj. VR is available for easy calibration. * Small and light weight design allow one hand operation. * Condenser microphone for high accuracy & long-term stability. * Low battery indicator. SPECIFICATIONS Display 18mm (0.7") LCD (Liquid Crystal Display), 3 1/2 digits. Function dB (A & C frequency weighting), Time weighting(Fast, Slow), Max. hold, AC & DC output. Measurement Range 3 ranges, 30 to 130 dB, input signal only. Resolution 0.1 dB. Accuracy Frequency weighting meet IEC 61672 class 2, calibrating input signal on 94 dB(31.5 Hz to 8 (23 ± 5 ℃) kHz), then the accuracy of frequency weighting is specified as following: 31.5 Hz - ± 3.5 dB, 63 Hz - ± 2.5 dB, 125 Hz - ± 2.0 dB 250 Hz - ± 1.9 dB, 500 Hz - ± 1.9 dB, 1 kHz - ± 1.4 dB 2 kHz - ± 2.6 dB, 4 kHz - ± 3.6 dB, 8 kHz - ± 5.6 dB Characteristics of A & C. Frequency A weighting - The characteristic is simulated as "Human Ear Listing" response. Typical, if making Weighting Network the environmental sound level measurement, always select to A weighting. C weighting - The characteristic is near the "FLAT" response. Typical, it is suitable for checking the noise of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment. Frequency 31.5 Hz to 8, 000 Hz. Calibrator B & K (Bruel & kjaer), multi-fuction acoustic calibrator, model : 4226. Microphone type Electric condenser microphone. Size of microphone 1/2 inch standard size. Range selector 30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step, with over & under range indicating. Time weighting Fast - t= 200 ms, Slow - t = 500 ms, (Fast & Slow) * "Fast" range is simulated the human ear response time weighting. "Slow" range is easy to get the average values of vibration sound level. Calibration * Build in external calibration VR, easy to calibrate by external screw driver. * Internal oscillation system, 1 KHz sine wave generator. Output Signal AC output - AC 0.5 Vrms corresponding to each range step. DC output - DC 0.3 to 1.3 VDC, 10 mV per dB. Out put impedance - 600 ohm. Output terminal 3.5 mm phone output terminal is provided for connection with analyzer, level recorder, tape recorder. Operating Temp. 0 ℃ to 50 ℃ ( 32 ℉ to 122 ℉ ). Operating Humidity Less than 80% RH Power Supply 006P DC 9V battery(heavy duty type). Power Consumption Approx. DC 6mA. Dimension 205 x 80 x 35 mm ( 8.1 x 3.2 x 1.4 inch). Weight 280 g/0.62 LB (including battery). Standard Accessories Instruction Manual ....................................... 1 PC. Calibration screw driver................................. 1 PC. Optional Accessories 94 dB Sound Calibrator, Model : SC-941. 94 dB/114 dB Sound Calibrator, Model : SC-942. Hard carrying case, Model : CA-06.
LUTRON EM-910 P, INCLUDED PROBE FOR ENVIRONMNET METERS EM-9000, EM-9100 HUMIDITY/TEMP., LIGHT, ANEMOMETER PROBE HUMIDITY/TEMP., LIGHT, ANEMOMETER PROBE Model : EM-910P Features * Included probe for Environmentl meters EM-9000, EM-9100 to make the humidity, Light and Air velocity, Temp., measurement. * Fast response time for the humidity measurement. * Anemometer can select the display unit to m/S, FPM, Km/h, mph, knot. * Light meter can select the display unit to LUX or Ft-cd. * Temperature measurement can default the display unit to °C or °F. * 0.1 degree resolution for temperature measurement. * Heavy duty & compact housing case. * Available for the HVAC applications. * Patent.
MECO-G R-CMT, POWERLINE AC CURRENT TRANSDUCER - ONE PHASE "MECO-G" AC Current Transducers convert a sinusoidal AC signal into a standard DC signal which is directly proportional to the measured input signal, These outputs are accurate, reliable, consistent and stable which are suitable for Telemetering, Dataloggers, PLC's, SCADA systems and control applications. GENERAL SPECIFICATION Accuracy ± 0.5% of Rated output, ± 0.2 % (Optional) Output Ripple 0.2% RMS Response Less than 0.5 Sec. Frequency 50 / 60 Hz. Zero Adj. ± 2% Min Span Adi. ±10 % Min. Operating Temp. 0° ~ 50° C (RH < 90 %) Non - Condensing Storage Temp -20°C ~ 70°C Overload Continuous 2 x Rated Current, 1.2 x Rated Voltage Breakdown Impulse Voltage 4.5KV, 1 x 40µs (without dewing.) Tempreature Coefficient 0.03% / °C. Dielectric Withstand Voltage between Input / Output / Power / Case 2 KV AC for 1 minute. Insulation Resistance (@ 500V DC) >100MΩ TYPE MODEL INPUT RANGES DIMENSION CURRENT (Single Phase) R-CMT 0-0.5, 1.2, 2.5, 5 Amps (anyone) Size 1 CURRENT (3 Phase 4 WIRE) R-CMT34* 0-0.5, 1, 2, 2.5, 5 Amps (anyone) Size 3 *Accuracy class 0.5% only available DC OUTPUT RANGES 0-1V ≥ 1KΩ 0-5V ≥ 5KΩ 1-5V ≥ 5KΩ 0-10V ≥ 10KΩ 2-10V ≥ 10KΩ 0-1mA ≤ 10KΩ 0-5mA ≤ 2KΩ 0-10mA ≤ 1KΩ 4-20mA ≤ 500Ω AUXILLIARY POWER SUPPLY 0-110 VAC ± 10% 50/60 Hz 2VA Approx. 0-220 VAC ± 10% 50/60 Hz 2VA Approx. 0-24 VDC ± 10% 2Watts Approx. 0-48 VDC ± 10% 2Watts Approx. 0-110 VDC ± 10% 2Watts Approx. 0-220 VDC ± 10% 2Watts Approx.