http://WWW.LUTRONMETER.COM
INSTRUMENTSZONE 571b78d19ec66f109851c64a False 166 1273
OK
background image not found
Found Update results for
'portable pen type ph meter'
5
LUTRON AM-4210_30MS + TYPE K/J TEMPERATURE MEASUREMENT, DATALOGGER, RS232/USB ANEMOMETER ANEMOMETER, + type K/J Temp. Model : AM-4210 * Microprocessor circuit ensures high accuracy and provides special functions and features. * Dual function display, show air velocity value and the Temp. value at the same time. * Low-friction ball vane wheels is accurate in both high and low velocities. * The portable anemometer provides fast, accurate readings, with digital readability and the convenience of a remote probe separately. * Five air velocity measurement units : m/s, km/h, ft/min, knots. mile/h. * Anemometer show the display unit with default. * 2 in 1, Anemometer + Thermometer ( type K/J ). * Thermocouple Thermometer can accept type K or type J Temp. probe with default. * Thermometer can default the display unit to°C or °F with default. * Meter can default auto power off or manual power off. * 0.1 degree resolution for temperature measurement. * Microcomputer circuit provides intelligent function and high accuracy. * Manual and auto data logger, with flexible sampling time selection, can save max. 1, 600-point data. * Records Maximum and Minimum readings with recall. * Data hold function for freezing the desired value. * Build in the input socket for DC 9V power adapter. * RS232 PC serial interface. * Few panel buttons, easy operation. * Built-in low battery indicator.
LUTRON AM-4210E AIR VELOCITY AND AIR TEMP. MEASUREMENT, ECONOMICAL TYPE ANEMOMETER ANEMOMETER Model : AM-4210E * Microprocessor circuit ensures high accuracy and provides special functions and features. * Dual function display, show air velocity value and the Temp. value at the same time. * Low-friction ball vane wheels is accurate in both high and low velocities. * The portable anemometer provides fast, accurate readings, with digital readability and the convenience of a remote probe separately. * Five air velocity measurement units : m/s, km/h, ft/min, knots. mile/h. * Anemometer show the display unit with default. * 2 in 1, Anemometer + Thermometer ( type K/J ). * Thermocouple Thermometer can accept type K or type J Temp. probe with default. * Thermometer can default the display unit to°C or °F with default. * Meter can default auto power off or manual power off. * 0.1 degree resolution for temperature measurement. * Microcomputer circuit provides intelligent function and high accuracy. * Records Maximum and Minimum readings with recall. * Data hold function for freezing the desired value. * Few panel buttons, easy operation. * Built-in low battery indicator.
We are the best supplier of Lutron brand instrument in indore. EM-9100 (HUMIDITY, LIGHT, AIR VELOCITY, TYPE K/J) Humidity, Anemometer, Light, Type K/J ENVIRONMENT METERModel : EM-9100* 4 in 1 : Humidity meter, Light meter, Anemometer, Type K/J thermometer.* Humidity : 10 to 95 %RH, 0 to 50 °C.* Light : 0 to 20, 000 Lux.* Anemometer : 0.4 to 25 m/s.
LUTRON SL-4001, IEC 61672 CLASS 2 SOUND LEVEL METER DIGITAL SOUND LEVEL METER Model : SL-4001 FEATURES * Large LCD display, easy to read. * Max. Hold function for stored the maximum value on display. * Frequency weighting networks are designed to meet the * Warning indicator for over and under load. IEC 61672 CLASS 2. * LCD display for low power consumption & clear read-out even * A & C weighting networks are conformity to standards. in bright ambient light condition. * Time weighting(FAST & SLOW) dynamic characteristic modes. * Used the durable, long-lasting components, including a strong, * AC/DC output for system expansion. light weight ABS-plastic housing case. * Build in adj. VR is available for easy calibration. * Small and light weight design allow one hand operation. * Condenser microphone for high accuracy & long-term stability. * Low battery indicator. SPECIFICATIONS Display 18mm (0.7") LCD (Liquid Crystal Display), 3 1/2 digits. Function dB (A & C frequency weighting), Time weighting(Fast, Slow), Max. hold, AC & DC output. Measurement Range 3 ranges, 30 to 130 dB, input signal only. Resolution 0.1 dB. Accuracy Frequency weighting meet IEC 61672 class 2, calibrating input signal on 94 dB(31.5 Hz to 8 (23 ± 5 ℃) kHz), then the accuracy of frequency weighting is specified as following: 31.5 Hz - ± 3.5 dB, 63 Hz - ± 2.5 dB, 125 Hz - ± 2.0 dB 250 Hz - ± 1.9 dB, 500 Hz - ± 1.9 dB, 1 kHz - ± 1.4 dB 2 kHz - ± 2.6 dB, 4 kHz - ± 3.6 dB, 8 kHz - ± 5.6 dB Characteristics of A & C. Frequency A weighting - The characteristic is simulated as "Human Ear Listing" response. Typical, if making Weighting Network the environmental sound level measurement, always select to A weighting. C weighting - The characteristic is near the "FLAT" response. Typical, it is suitable for checking the noise of machinery (Q.C. check) & knowing the sound pressure level of the tested equipment. Frequency 31.5 Hz to 8, 000 Hz. Calibrator B & K (Bruel & kjaer), multi-fuction acoustic calibrator, model : 4226. Microphone type Electric condenser microphone. Size of microphone 1/2 inch standard size. Range selector 30 to 80 dB, 50 to 100 dB, 80 to 130 dB, 50 dB on each step, with over & under range indicating. Time weighting Fast - t= 200 ms, Slow - t = 500 ms, (Fast & Slow) * "Fast" range is simulated the human ear response time weighting. "Slow" range is easy to get the average values of vibration sound level. Calibration * Build in external calibration VR, easy to calibrate by external screw driver. * Internal oscillation system, 1 KHz sine wave generator. Output Signal AC output - AC 0.5 Vrms corresponding to each range step. DC output - DC 0.3 to 1.3 VDC, 10 mV per dB. Out put impedance - 600 ohm. Output terminal 3.5 mm phone output terminal is provided for connection with analyzer, level recorder, tape recorder. Operating Temp. 0 ℃ to 50 ℃ ( 32 ℉ to 122 ℉ ). Operating Humidity Less than 80% RH Power Supply 006P DC 9V battery(heavy duty type). Power Consumption Approx. DC 6mA. Dimension 205 x 80 x 35 mm ( 8.1 x 3.2 x 1.4 inch). Weight 280 g/0.62 LB (including battery). Standard Accessories Instruction Manual ....................................... 1 PC. Calibration screw driver................................. 1 PC. Optional Accessories 94 dB Sound Calibrator, Model : SC-941. 94 dB/114 dB Sound Calibrator, Model : SC-942. Hard carrying case, Model : CA-06.
LUTRON AQ-9901 SD AIR QUALITY METER FEATURES * Real time recorder, save the data into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic analysis by themselves. under the Excel software. * At the same time, the SD memory card can record 3 probe\'s data ( %RH/CO2/O2/Temp. or %RH/CO2/CO/Temp. ) along with the time information into the one Excel file at the same time. * Manual datalogger is available, during execute the manual datalogger function, it can set the different location no. ( position 1 to position 99 ). * Air quality measurement application, multi-function : CO2 (Carbon dioxide ), CO ( Carbon monoxide ), O2 ( Oxygen in air ), Humidity, temperature measurement. * CO2range:0to4, 000ppmx1ppm. * O2range:0to30.0%x0.1%. * COrange:0to1, 000ppmx1ppm. * Humidity range: 10 to 95 %RH. * Dew point Temp. and Wet bulb Temp. measurement. * Temp. range : 0 to 50.0 °C, °C/°F. * CO2 sensor : NDIR, long term reliability. * CO, O2 sensor : Galvanic cell type. * Humidity sensor : Precision capacitance sensor * Alarm setting with the beeper sound output. * Sampling time for data recorder is 2 seconds to 8 hours. * Complete set with 4 probes :CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe, Humidity/Temp. probe, main meter and the hard carrying case. * Separate probe, easy for remote measurement. * Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional. * RS232/USB computer interface.
1
false