http://WWW.LUTRONMETER.COM
INSTRUMENTSZONE 571b78d19ec66f109851c64a False 166 1273
OK
background image not found
Found Update results for
'upload data'
5
LUTRON AQ-9901 SD AIR QUALITY METER FEATURES * Real time recorder, save the data into the SD memory card and can be down load to the Excel, extra software is no need. User can make the further data or graphic analysis by themselves. under the Excel software. * At the same time, the SD memory card can record 3 probe\'s data ( %RH/CO2/O2/Temp. or %RH/CO2/CO/Temp. ) along with the time information into the one Excel file at the same time. * Manual datalogger is available, during execute the manual datalogger function, it can set the different location no. ( position 1 to position 99 ). * Air quality measurement application, multi-function : CO2 (Carbon dioxide ), CO ( Carbon monoxide ), O2 ( Oxygen in air ), Humidity, temperature measurement. * CO2range:0to4, 000ppmx1ppm. * O2range:0to30.0%x0.1%. * COrange:0to1, 000ppmx1ppm. * Humidity range: 10 to 95 %RH. * Dew point Temp. and Wet bulb Temp. measurement. * Temp. range : 0 to 50.0 °C, °C/°F. * CO2 sensor : NDIR, long term reliability. * CO, O2 sensor : Galvanic cell type. * Humidity sensor : Precision capacitance sensor * Alarm setting with the beeper sound output. * Sampling time for data recorder is 2 seconds to 8 hours. * Complete set with 4 probes :CO2/Temp. probe, O2/Temp. probe, CO/Temp. probe, Humidity/Temp. probe, main meter and the hard carrying case. * Separate probe, easy for remote measurement. * Meter can cooperate with 2 GB to 16 GB SD card, SD card is optional. * RS232/USB computer interface.
METRAVI CET-04 CLAMP ON GROUND RESISTANCE TESTER MODEL NO. CET-04 4 Digits LCD, 28mm Clamp Jaw Dia, Data Hold, Open Clamp Jaw Indication, Range 0.010 to 1000 Ohms. Maximum Resolution 0.001 Ohms. With Leakage Current Measurement up to 20A. Description Widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment. Can measure the leakage current of ground wire. Clamp Earth Resistance Tester measures the integrated value of ground resistance and resistance lead. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster. Clamp Earth Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in the occasion where traditional methods are unworkable. The latest updated series Clamp Earth Resistance Testers have better performance: Boot up instantly, avoid boot up errors; More reliable battery cover, convenient to change battery; Wider range, larger memory; Optional RS232 interface, available to transfer data to PC and generate report files, easy to analyse or backup data. Clamp Jaw: 32mm Display: 4 digit Backlit LCD Resistance Range: 0.01 to 1200 Ohms Resolution: 0.01 Ohms Current range:0.00-20.00A Resolution: 0.05mA Storage of Measured Data: 99 Data Setting of Resistance Alarm Critical Value: 1 – 199 Ohms Setting Range of Current Alarm Critical Value:1-499mA Data Hold, Auto Power Off
LUTRON AM-4210_30MS + TYPE K/J TEMPERATURE MEASUREMENT, DATALOGGER, RS232/USB ANEMOMETER ANEMOMETER, + type K/J Temp. Model : AM-4210 * Microprocessor circuit ensures high accuracy and provides special functions and features. * Dual function display, show air velocity value and the Temp. value at the same time. * Low-friction ball vane wheels is accurate in both high and low velocities. * The portable anemometer provides fast, accurate readings, with digital readability and the convenience of a remote probe separately. * Five air velocity measurement units : m/s, km/h, ft/min, knots. mile/h. * Anemometer show the display unit with default. * 2 in 1, Anemometer + Thermometer ( type K/J ). * Thermocouple Thermometer can accept type K or type J Temp. probe with default. * Thermometer can default the display unit to°C or °F with default. * Meter can default auto power off or manual power off. * 0.1 degree resolution for temperature measurement. * Microcomputer circuit provides intelligent function and high accuracy. * Manual and auto data logger, with flexible sampling time selection, can save max. 1, 600-point data. * Records Maximum and Minimum readings with recall. * Data hold function for freezing the desired value. * Build in the input socket for DC 9V power adapter. * RS232 PC serial interface. * Few panel buttons, easy operation. * Built-in low battery indicator.
DATA LOGGERS CM-9930R/ DL-9602SD SET (COMPLETE SET INCLUDES: CM-9930R, DL-9602SD, CABLE UPCB-03) CM-9930R/ DL-9602SD SET (COMPLETE SET INCLUDES: CM-9930R, DL-9602SD, CABLE UPCB-03) Clamp meter with DAta recorder setModel : CM-9930R/DL-962SD SET* Complete set are includes :1. Clamp meter CM-9930R.2. SD card data recorder, DL-9602SD.3. Interface cable, UPCB-03.* Complete set is used to record the Clamp meter\'s measurement values ( ACA, DCA, ACV. DCV ohms....) with the real time information. INR 8100 FOR MORE DETAILS PLEASE LOGIN I-ZONE.IN
METRAVI DT-230 DIGITAL AC/DC CLAMP METER MODAL NO. DT-230 3-3/4 DIGITS, LCD, DATA HOLD, 30MM JAW SIZE, AC/DC VOLTAGE, AC/DC CURRENT UP TO 400A, RESISTANCE, CAPACITANCE, TEMPERATURE, FREQUENCY, DIODE & CONTINUITY TEST. Description · Data Hold Facility · Built-in Non Contact Voltage Detector · Fully Protected up to 600V DC/AC RMS in all ranges including Frequency, Resistance, Capacitance and Continuity test · Low Battery and Over Range Indication · Display: 3-3/4 Digits 3999 Counts Backlit LCD · Confirms to CAT III 600V · Clamp Jaw Dia: 30mm · DC Voltage : 0 - 400m/4/40/400/600V. · Accuracy : ±0.8% · AC Voltage : 0 - 400m/4/40/400/600V. · Accuracy : ±1.5% · DC Current : 0 - 40/400A. · Accuracy : ±2.5% · AC Current : 0 - 40/400A. · Accuracy : ±2.5% · Resistance : 0 - 400/4k/40k/400k/4M/40M.Ohms · Accuracy : ±1.0% · Temperature : -20°C to 760°C / -4°F to 1400°F · Accuracy : ±3.0% · Frequency : 10 ~ 10KHz · Accuracy : ±1.5% · Capacitance : 0 - 40n/400n/4u/40u/100uF · Accuracy : ±3.0% · Diode Test and Continuity Test · Confirms to CE, IEC 61010, CAT-III 600V
1
false